Brand:NTH
High rotary speed with coolant connection, Coolant can be fed from the cylinder back parts.
The safety check valve and pressure relief valve are built in the cylinder.
The drain port should be ind🎶ependenꩲtly connected to oil tank to avoid back pressure.
Size unit: mm
Spec
Model
|
Piston area cm2
Extend
|
Piston area cm2
Retract
|
Piston stroke
mm
|
Max RPM
|
SL-75
|
42.6
|
37.1
|
15
|
6000
|
SL-100
|
77
|
71.5
|
20
|
6000
|
SL-125
|
121.2
|
113.1
|
25
|
6000
|
SL-150
|
175.2
|
160.8
|
30
|
5500
|
SL-200
|
312.5
|
290.4
|
35
|
5500
|
Spec
Model
|
Max.Operating Pressure
Mpa(kgf/cm2)
|
coolant connection
Max.pressure
Mpa(kgf/cm2)
|
I
kg*m2
|
Weight
kg
|
SL-75
|
4.0(40)
|
3.5(35)
|
0.01
|
3.1
|
SL-100
|
4.0(40)
|
3.5(35)
|
0.04
|
4.6
|
SL-125
|
4.0(40)
|
3.5(35)
|
0.06
|
7.1
|
SL-150
|
4.0(40)
|
3.5(35)
|
0.1
|
9.7
|
SL-200
|
4.0(40)
|
3.5(35)
|
0.3
|
15.6
|
Spec
Model
|
A
|
B
|
C
|
D1
|
D2
|
E H7
|
F
|
G Max
|
G Min
|
H
|
H1
|
H2
|
J
|
K
|
L
|
L1
|
L2
|
M H8
|
N
|
SL-75
|
75
|
15
|
107
|
90
|
90
|
65
|
30
|
45
|
30
|
57
|
42
|
137
|
194
|
M20×2.5
|
6~M8×16
|
M8×60
|
12
|
21
|
35
|
SL-100
|
100
|
20
|
132
|
115
|
100
|
80
|
30
|
45
|
25
|
72
|
42
|
137
|
209
|
M20×2.5
|
6~M10×20
|
M8×75
|
12
|
21
|
35
|
SL-125
|
125
|
25
|
160
|
140
|
130
|
110
|
35
|
35
|
25
|
82
|
41
|
136
|
218
|
M24×3.0
|
6~M12×20
|
M8×85
|
12
|
25
|
45
|
SL-150
|
150
|
30
|
190
|
170
|
130
|
110
|
45
|
45
|
25
|
95
|
39
|
134
|
230
|
M30×3.5
|
12~M12×24
|
M10×100
|
16
|
31
|
45
|
SL-200
|
200
|
35
|
245
|
220
|
145
|
120
|
55
|
55
|
35
|
115
|
36
|
132
|
248
|
M36×4.0
|
12~M16×30
|
M10×125
|
21
|
37
|
60
|
Su🐻bject to technology changes without prior information